In operation theater during cauterization, the electric current passing from a single electrode is called:

Appeared in: Combined AIIMS - 2020 (Jodhpur, Bhopal, Patna, Raipur)

Explanation

  • In monopolar electrosurgery, the electric circuit consists of a generator, a single active electrode, the patient, and a return electrode (grounding pad).
  • The electric current flows from the single active electrode into the patient's tissue to achieve cutting or coagulation.
  • The current exits the patient's body via a large grounding pad placed on the skin, which safely disperses the energy.
  • The provided image visually confirms that monopolar cautery uses a single active handpiece, whereas bipolar uses a two-pronged forceps.

Why Other Options Were Wrong

  • Option A: Chemical cautery uses caustic chemical substances to destroy tissue or achieve hemostasis, not an electric current.
  • Close distractor alert - Option C: In bipolar cautery, the electric current passes directly between two closely approximated electrodes (the tips of a forceps), not from a single electrode through the patient's body.
  • Option D: This option is invalid because chemical cautery does not involve electric current.

Related Visual

side comparison of monopolar and bipolar electrosurgical circuits, highlighting the single active electrode and grounding pad in monopolar versus the two-pronged forceps in bipo...
Clinical Relevance
  • Nursing practice connection: This is primarily an exam-oriented knowledge point with limited direct bedside application, so retain Principles of electrosurgery and types of cauterization circuits as background academic context rather than a clinical decision trigger.
  • Proper placement of the grounding pad in monopolar cautery is critical; if partially dislodged, the decreased surface area can concentrate the exiting current and cause severe patient burns.
  • Patients with pacemakers or implantable cardioverter-defibrillators require special precautions because stray monopolar current can interfere with the device.
  • What if? If a patient has a pacemaker and requires surgery, the surgical team would likely switch to bipolar cautery or a Harmonic scalpel to prevent electrical interference with the cardiac device.
How to Approach the Question
  • Identify the core subject: The question asks about a specific type of electrosurgery based on its electrical circuit.
  • Analyze the key phrase: Focus on 'current passing from a single electrode'.
  • Recall the definitions: 'Mono' means one (single active electrode), while 'Bi' means two (two electrodes on the instrument tip).
  • Eliminate non-electrical options: Chemical cautery does not use electricity, ruling out options A and D.
  • Select the matching term: Monopolar cautery perfectly fits the description of a single active electrode system.
Concept Tested & Keywords
  • Concept Tested: Principles of electrosurgery and types of cauterization circuits
  • Stem keywords: operation theater, cauterization, electric current, single electrode
  • Lead-in keywords: called
  • Clinical cues: single electrode indicates the specific type of electrical circuit being used