SGPGI Nursing Officer-2023
Fundamental of Nursing
Easy

While a patient is receiving tube feeding, the height of the container should be maintained?

Appeared in: SGPGI Nursing Officer-2023

Explanation

  • The standard height for a gravity tube feeding container is approximately 45 cm (or 18 inches) above the level of the patient's stomach.
  • This height provides an optimal flow rate, allowing the feeding to be administered over a safe period (typically 30-45 minutes).
  • It balances the need for a consistent flow with the prevention of complications associated with infusions that are too rapid or too slow.
  • This practice is based on the principle of gravity, where the height difference creates the pressure needed for the liquid to flow.

Why Other Options Were Wrong

  • Option A: A height of 18 cm is too low for an effective gravity feed. The flow rate would be extremely slow or may stop altogether.
  • Option C: A height of 72 cm is too high. This would cause the formula to infuse too rapidly, leading to a bolus effect.
  • Option D: A height of 22 cm is also too low for an effective gravity feed, similar to the 18 cm option.

Related Visual

Visual explanation — Related Visual
Clinical Relevance
  • Nursing practice connection: Use the key finding related to Principles of Enteral Nutrition Administration to guide bedside assessment, documentation, and the next nursing action.
  • Proper administration of tube feeding is a fundamental nursing skill critical for patient safety and nutritional support.
  • Incorrectly managing the flow rate can lead to serious complications, including aspiration pneumonia, which has a high mortality rate.
  • Nurses must not only set up the feed correctly but also monitor the patient's tolerance throughout the infusion.
How to Approach the Question
  • First, identify that the question is asking for a standard parameter in a common nursing procedure: gravity tube feeding.
  • Recall the physical principle involved: gravity. The height of the fluid source determines the pressure and thus the flow rate.
  • Consider the clinical goals: the feeding should be slow and steady, not too fast (to prevent aspiration and GI upset) and not too slow (to ensure adequate nutrition and prevent clogging).
  • Evaluate the given options. Eliminate the extremes: 18 cm and 22 cm are too low, likely resulting in a very slow flow. 72 cm is very high and would cause a dangerously fast flow.
  • Select the option that represents the established, safe standard. 45 cm (18 inches) is the commonly accepted height for balancing safety and effectiveness in gravity feeding.
Concept Tested & Keywords
  • Concept Tested: Principles of Enteral Nutrition Administration
  • Stem keywords: patient, tube feeding, height of the container
  • Lead-in keywords: should be maintained

Question ID

QhuBAHQz_e11V4-fzI5Zyb

Reference Book

E6 Nursing Fundamentals Taylor p. 523-525

E6 Nursing Brunner Adult Health 3SA Vol 1 Part 2 p. 96-98

Practise the full SGPGI Nursing Officer-2023

Attempt every question from this paper in a timed mock, then review the full solution for each one.

More Nursing procedures Questions

More SGPGI Nursing Officer-2023 Questions