DSSSB - 29 August 2019 (Shift-2)
Medical & Surgical Nursing
Easy

Out of the following methods of oxygen administration system, which method comes under low flow system?

Appeared in: DSSSB - 29 August 2019 (Shift-2)

Explanation

  • A simple face mask is a low-flow oxygen delivery system because it does not provide the patient's entire inspiratory flow needs.
  • The oxygen provided is diluted with entrained room air through side ports, resulting in a variable FiO₂ (fraction of inspired oxygen), typically between 35% and 50%.
  • The final FiO₂ depends on the oxygen flow rate, the fit of the mask, and the patient's respiratory rate and depth.
  • A minimum flow rate of 5 L/min is required to flush exhaled carbon dioxide from the mask.

Why Other Options Were Wrong

  • Option B: The Venturi mask is a high-flow system, not a low-flow system.
  • Option C: An oxygen hood is a high-flow system specifically designed for infants.
  • Option D: A tracheostomy mask (or collar) is typically used as part of a high-flow system to deliver humidified oxygen directly to a patient's artificial airway.

Related Visual

Visual explanation — Related Visual
Clinical Relevance
  • Nursing practice connection: This is primarily an exam-oriented knowledge point with limited direct bedside application, so retain Classification of Oxygen Delivery Systems (Low-Flow vs. High-Flow) as background academic context rather than a clinical decision trigger.
  • Choosing the correct oxygen delivery system is a critical nursing responsibility. Using a low-flow device when a high-flow, fixed-performance device is needed can lead to inadequate oxygenation or, in some cases (like COPD), respiratory depression.
  • A key safety consideration for a simple face mask is ensuring the flow rate is at least 5 L/min. Below this rate, the mask can trap exhaled carbon dioxide, leading to rebreathing and hypercapnia.
  • What if the patient had COPD and required an FiO₂ of 28%? The simple face mask would be inappropriate. The nurse should use a Venturi mask with the 28% (blue) adapter to deliver a precise concentration and prevent CO₂ retention.
How to Approach the Question
  • First, understand the question's core concept: the classification of oxygen delivery systems.
  • Recall the key difference between low-flow and high-flow systems. Low-flow systems provide a variable FiO₂ because they don't meet the patient's full inspiratory demand. High-flow systems provide a fixed, precise FiO₂ by meeting or exceeding this demand.
  • Evaluate each option against this definition.
  • Simple face mask: Does it provide a fixed FiO₂? No, it has side ports for room air entrainment. This makes it a low-flow system.
  • Venturi mask: Is it known for precision? Yes, it uses entrainment valves for a fixed FiO₂. This makes it a high-flow system.
  • Oxygen hood/Tracheostomy mask: Are these used for partial or total respiratory support? They are designed to provide the total required gas flow, making them high-flow systems.
Concept Tested & Keywords
  • Concept Tested: Classification of Oxygen Delivery Systems (Low-Flow vs. High-Flow)
  • Stem keywords: oxygen administration, low flow system
  • Lead-in keywords: which method

Question ID

Q_RPKasvWy8grJ1HBn8VYD

Reference Book

E6 Nursing Fundamentals Taylor p. 731-733

E6 Nursing Fundamentals Potter Perry 12e Part 5 p. 7-9

Practise the full DSSSB - 29 August 2019 (Shift-2)

Attempt every question from this paper in a timed mock, then review the full solution for each one.

More Gas Exchange and Respiratory Function Questions

More DSSSB - 29 August 2019 (Shift-2) Questions