The blue-colored cannula corresponds to a 22 Gauge (G) size.
A 22G cannula has a very small internal diameter, which is generally unsuitable for transfusing viscous fluids like blood.
Using a small-bore cannula for blood transfusion significantly increases the risk of mechanical hemolysis (destruction of red blood cells).
The flow rate through a 22G cannula is very slow (approximately 36 mL/min), making it difficult to complete a transfusion within the safe 4-hour window.
Due to these factors, the blue 22G cannula is the least used and least appropriate choice for blood transfusion among the given options.
Why Other Options Were Wrong
Option A: A gray cannula is 16G. It is a large-bore cannula specifically used for rapid, high-volume fluid and blood administration, especially in trauma and major surgery. It is not the 'least used'; it is essential for specific critical situations.
Option B: A green cannula is 18G. This is the most common and standard-of-care cannula for routine blood transfusions in adults. It provides an optimal balance between flow rate and patient comfort.
Option C: A pink cannula is 20G. It is considered an acceptable and frequently used alternative for blood transfusions, particularly when a patient's veins cannot accommodate a larger 18G cannula. It is not the 'least used'.
Related Visual
Visual 1: Chart: A visual chart displaying IV cannula colors, their corresponding gauge sizes, flow rates, and primary clinical indications. This would help learners quickly associate the color with the size and use.
Visual 2: Infographic: An infographic illustrating the concept of hemolysis, showing how a narrow cannula can damage red blood cells compared to a wider cannula during blood transfusion.
Clinical Relevance
Nursing practice connection: Knowing IV Cannula Selection for Blood Transfusion helps nurses interpret findings accurately and avoid errors in routine assessment, medication administration, and patient teaching.
A nurse's primary responsibility during blood administration includes selecting the appropriate IV access. Choosing an incorrectly sized cannula can lead to patient harm (hemolysis, fluid overload) and treatment failure (incomplete transfusion).
Patient assessment is key. The nurse must assess the patient's vein size and condition to balance the need for a large-bore cannula with the feasibility of insertion.
In an emergency, if only a small-gauge (e.g., 22G) IV is available, the nurse must notify the healthcare provider. The transfusion may proceed with caution, but it requires close monitoring for signs of hemolysis and may need a pressure bag to maintain flow, further increasing hemolysis risk.
How to Approach the Question
First, identify the core concept of the question, which is the relationship between IV cannula size and its suitability for blood transfusion.
The keyword is 'Least used'. This means you are looking for the option that is least appropriate or most problematic for a blood transfusion.
Recall the standard color-coding for IV cannulas and their corresponding gauge sizes. Remember that a smaller gauge number means a larger cannula diameter.
Evaluate each option: Gray (16G - large, for trauma), Green (18G - standard for blood), Pink (20G - acceptable for blood), Blue (22G - small, for fragile veins).
Compare the suitability of each size for blood transfusion. A smaller cannula (higher gauge number) is less suitable due to slow flow and risk of hemolysis.
Conclude that the Blue (22G) cannula is the least suitable and therefore the 'least used' for routine adult blood transfusions among the choices.
Concept Tested & Keywords
Concept Tested: IV Cannula Selection for Blood Transfusion
Stem keywords: cannula, blood transfusion
Lead-in keywords: Least used
Negative lead-in flag: LEAST changes the reasoning strategy; look for the exception or incorrect statement rather than the true statement.
Question ID
QmMsKYVcyk9A5eQFwFWDpf
Practise the full NORCET 2 -2021 (Shift-2)
Attempt every question from this paper in a timed mock, then review the full solution for each one.