Easy

For effective sterilization in the autoclave, the temperature should be how much?

Appeared in: AIIMS Raipur NO- 2019 (shift 3rd)

Explanation

  • Autoclaving utilizes pressurized steam to achieve a temperature of 121°C, which is above the normal boiling point of water.
  • This combination of high temperature and moist heat is necessary to destroy all forms of microbial life, including highly resistant bacterial endospores.
  • The standard cycle for effective sterilization is maintaining 121°C at 15 psi pressure for a minimum of 15 minutes.

Why Other Options Were Wrong

  • Option A: 121 degrees Fahrenheit is approximately 49.4°C, a temperature that is far too low for sterilization and insufficient for most disinfection.
  • Option C: 100 degrees Fahrenheit is approximately 37.8°C, which is close to human body temperature. This temperature can promote the growth of many bacteria rather than killing them.
  • Option D: 100°C is the boiling point of water. While boiling kills most vegetative bacteria, it does not reliably eliminate bacterial spores. Therefore, it is classified as disinfection, not sterilization.

Related Visual

Visual explanation — Related Visual
Clinical Relevance
  • Nursing practice connection: This is primarily an exam-oriented knowledge point with limited direct bedside application, so retain Principles of Autoclave Sterilization as background academic context rather than a clinical decision trigger.
  • Proper autoclave sterilization is a fundamental practice in infection control, critical for preventing healthcare-associated infections (HAIs), especially surgical site infections (SSIs).
  • Nurses play a key role in the sterilization process, including ensuring instruments are cleaned beforehand, packs are loaded correctly to allow steam penetration, and cycle parameters are monitored using chemical and biological indicators.
  • What if? If a biological indicator test (containing Geobacillus stearothermophilus spores) from an autoclave load is positive, it indicates a sterilization failure. The entire load must be considered non-sterile, recalled, and reprocessed. The autoclave must be investigated and serviced before further use.
How to Approach the Question
  • Identify the key terms in the question: 'autoclave' and 'effective sterilization'.
  • Recall that 'sterilization' means the elimination of all microbial life, including highly resistant bacterial spores.
  • Recognize that this requires conditions more intense than simple boiling, which occurs at 100°C. This immediately makes 100°C a less likely answer for sterilization.
  • Differentiate between the Celsius (°C) and Fahrenheit (°F) scales. Note that the Fahrenheit options (121°F ≈ 49°C; 100°F ≈ 38°C) represent temperatures that are too low.
  • Based on this, the only plausible option for achieving sterilization is a temperature above 100°C.
  • Select the option that matches the standard temperature for autoclaving, which is a core piece of knowledge in microbiology and infection control.
Concept Tested & Keywords
  • Concept Tested: Principles of Autoclave Sterilization
  • Stem keywords: autoclave, sterilization, temperature
  • Lead-in keywords: effective, how much
  • Negative lead-in flag: false

Question ID

Q1Zoo-iSdWkRE4XLWF6dcJ

Reference Book

E6 Parks TextBook of Preventive & Social Medicine part 1 — Subpart A (pp 26-201 of 604) p. 127-129

E6 Microbiology OneStop Sastry p. 50-52

Practise the full AIIMS Raipur NO- 2019 (shift 3rd)

Attempt every question from this paper in a timed mock, then review the full solution for each one.