Which statement regarding IV cannula size and color is incorrect?

Appeared in: AIIMS Delhi NO - 2017

Explanation

  • The statement '24 / Gray' is incorrect.
  • According to the universal color-coding system for IV cannulas, a 24-gauge cannula is designated by the color Yellow.
  • The color Gray is used to identify a 16-gauge cannula, which is a much larger size used for rapid fluid or blood administration.

Why Other Options Were Wrong

  • Option B: This statement is correct. A 22-gauge cannula is universally color-coded as Blue.
  • Option C: This statement is correct. A 20-gauge cannula is color-coded as Pink.
  • Option D: This statement is correct. An 18-gauge cannula is color-coded as Green.

Related Visual

Visual explanation — Related Visual
Clinical Relevance
  • Nursing practice connection: This is primarily an exam-oriented knowledge point with limited direct bedside application, so retain IV cannula gauge and color coding as background academic context rather than a clinical decision trigger.
  • Rapid identification of cannula size by color is a critical nursing skill, especially in emergencies, as it allows for quick selection of the appropriate device for the required flow rate.
  • Using a cannula that is too small for the prescribed therapy (e.g., using a 24G for a rapid blood transfusion) can lead to hemolysis and delayed treatment.
  • What if? If a patient requires rapid infusion of a viscous fluid like a blood product, selecting a green (18G) or pink (20G) cannula is appropriate. Choosing a blue (22G) or yellow (24G) cannula would be incorrect as the flow rate would be too slow and could damage blood cells.
How to Approach the Question
  • First, identify the core of the question, which is to find the INCORRECT pairing of an IV cannula gauge and its color.
  • Recall the standard color-coding system for IV cannulas. Remember that a smaller gauge number means a larger cannula.
  • Systematically evaluate each option against the standard color codes.
  • Option A: 24G is Yellow, not Gray. This statement is incorrect.
  • Option B: 22G is Blue. This statement is correct.
  • Option C: 20G is Pink. This statement is correct.
Concept Tested & Keywords
  • Concept Tested: IV cannula gauge and color coding
  • Stem keywords: IV cannula, size, color
  • Lead-in keywords: incorrect
  • Negative lead-in flag: The question asks for the INCORRECT statement.

Question ID

QLJViTuOrA4fqeUd1WS5Si

Reference Book

E6 Nursing Fundamentals Taylor p. 1092-1094