Pressure used in suction & evacuation in MTP?

Appeared in: NORCET 5 Prelims - Sept 2023 (Shift-1)

Explanation

  • The standard negative pressure for Electric Vacuum Aspiration (EVA) for MTP is 400-600 mm Hg.
  • This pressure range provides the optimal balance between effectively removing the products of conception and ensuring patient safety.
  • Using the correct pressure minimizes the risk of uterine trauma, perforation, and excessive bleeding.
  • This procedure is distinct from Manual Vacuum Aspiration (MVA), which uses a much lower pressure (around 60 mm Hg).

Why Other Options Were Wrong

  • Option A: A pressure of 200-300 mm Hg is generally considered too low for effective evacuation of the uterus.
  • Option C: A pressure of 600-800 mm Hg is excessively high for a standard EVA procedure.
  • Option D: A pressure of 800-1000 mm Hg is dangerously high and is never used in this procedure.

Related Visual

Visual explanation — Related Visual
  • Visual 1: Diagram - A comparative diagram showing the setup for Electric Vacuum Aspiration (EVA) with its electric pump and a Manual Vacuum Aspiration (MVA) kit with its handheld syringe. This helps visualize the difference in equipment.
  • Visual 2: Chart - A chart illustrating the different pressure ranges for uterine aspiration. It should show the optimal range (400-600 mm Hg) as safe and effective, while highlighting lower ranges as 'ineffective' and higher ranges as 'dangerous/high-risk'.
Clinical Relevance
  • Nursing practice connection: This is primarily an exam-oriented knowledge point with limited direct bedside application, so retain Pressure settings for suction evacuation in Medical Termination of Pregnancy (MTP) as background academic context rather than a clinical decision trigger.
  • A nurse's role includes preparing the suction apparatus, ensuring it is functioning correctly, and verifying the pressure setting with the physician before the procedure begins.
  • During the procedure, the nurse monitors the patient's vital signs, assesses blood loss, and provides emotional support. Post-procedure, the nurse monitors for signs of complications like hemorrhage, infection, or severe pain.
  • What if? If there is a power outage during an EVA procedure, the team must be prepared to switch to a Manual Vacuum Aspiration (MVA) kit, which does not require electricity. The nurse should know the location and setup of the MVA kit for such emergencies.
How to Approach the Question
  • First, identify the key terms in the question: 'Pressure', 'suction & evacuation', and 'MTP'. This points to a question about the technical parameters of a specific medical procedure.
  • Recognize that 'suction and evacuation' typically refers to Electric Vacuum Aspiration (EVA), which is different from Manual Vacuum Aspiration (MVA).
  • Recall the standard, safe, and effective negative pressure range for EVA used in first-trimester MTP.
  • Evaluate the given options to find the one that matches the standard range (400-600 mm Hg).
  • Eliminate other options by reasoning that lower pressures are ineffective and higher pressures are dangerous.
Concept Tested & Keywords
  • Concept Tested: Pressure settings for suction evacuation in Medical Termination of Pregnancy (MTP)
  • Stem keywords: Pressure, suction & evacuation, MTP
  • Lead-in keywords: BEST, MOST RELEVANT CLUE
  • Negative lead-in flag: false

Question ID

Qt9Q5De0usJRHfUnH-Lj2d

Practise the full NORCET 5 Prelims - Sept 2023 (Shift-1)

Attempt every question from this paper in a timed mock, then review the full solution for each one.

More Family Planning Questions

More NORCET 5 Prelims - Sept 2023 (Shift-1) Questions