MP NHM CHO-2024 (Shift-1)
Obstetrics and Midwifery Nursing
Medium

Organize the steps in the accurate sequence for the placement of a PPIUCD.

Appeared in: MP NHM CHO-2024 (Shift-1)

Explanation

  • The correct sequence for PPIUCD placement follows a logical procedural flow: Insertion → Positioning → Withdrawal.
  • Step A (Insertion): The procedure must begin by introducing the device into the uterine cavity.
  • Step B (Fundal Placement): After insertion, the device must be advanced to its final, correct position at the uterine fundus to ensure efficacy and prevent expulsion.
  • Step C (Withdrawal): Only after the device is correctly placed can the insertion instrument be safely removed.
  • This logical progression confirms that the only correct order is A → B → C.

Why Other Options Were Wrong

  • Option B: This sequence (CBA) is illogical as it begins with withdrawing the instrument (C) before it has even been inserted (A) or placed (B).
  • Option C: This sequence (ACB) is incorrect because it involves withdrawing the instrument (C) after initial insertion (A) but before proper fundal placement (B). This would leave the IUCD in the lower uterine segment, leading to a very high risk of expulsion.
  • Option D: This sequence (BCA) is illogical. It suggests placing the device at the fundus (B) as the first step, which is impossible without first inserting it through the cervix into the uterus (A).

Related Visual

Visual explanation — Related Visual
  • Visual 1: Diagram - A series of three illustrations showing the correct sequence of PPIUCD insertion. The first shows the forceps entering the cervix. The second shows the forceps at the uterine fundus. The third shows the forceps being withdrawn, leaving the IUD in place.
Clinical Relevance
  • Nursing practice connection: This is primarily an exam-oriented knowledge point with limited direct bedside application, so retain Procedural sequence of Postpartum Intrauterine Contraceptive Device (PPIUCD) placement as background academic context rather than a clinical decision trigger.
  • Correct fundal placement is the single most important factor in reducing the risk of IUD expulsion, which is a primary concern with postpartum insertions.
  • Nurses play a vital role in assisting with the procedure, ensuring sterile technique is maintained to prevent infection, and providing patient counseling on follow-up care and warning signs (e.g., checking for strings, signs of infection, or expulsion).
  • The technique of opening the forceps jaws slightly and sweeping them to the side during withdrawal is critical to avoid catching the IUD strings, which would pull the device out of its correct position.
How to Approach the Question
  • First, identify the core task of the question, which is to arrange the steps of a medical procedure in the correct order.
  • Analyze the description or image for each step. In this case, 'A' represents initial insertion, 'B' represents final positioning, and 'C' represents the removal of the tool.
  • Apply basic logic for any insertion procedure: you must first introduce the object, then move it to its final correct location, and finally, remove the tool used for insertion.
  • Based on this logic, the sequence must be: Initial Insertion (A) → Final Placement (B) → Tool Withdrawal (C).
  • This establishes the correct sequence as A → B → C.
  • Finally, match this derived sequence to the given options to find the correct answer.
Concept Tested & Keywords
  • Concept Tested: Procedural sequence of Postpartum Intrauterine Contraceptive Device (PPIUCD) placement.
  • Stem keywords: PPIUCD, placement, sequence, steps
  • Lead-in keywords: Organize, accurate sequence

Question ID

QVE50hh2rdIJ-WIZIRcDDD

Practise the full MP NHM CHO-2024 (Shift-1)

Attempt every question from this paper in a timed mock, then review the full solution for each one.

More Gynecology & Contraception Questions

More MP NHM CHO-2024 (Shift-1) Questions