JSSH Staff Nurse - 2019
Obstetrics and Midwifery Nursing
Easy

Amniotic fluid index is measured by?

Appeared in: JSSH Staff Nurse - 2019

Explanation

  • The Amniotic Fluid Index (AFI) is a quantitative estimate of amniotic fluid volume, a key indicator of fetal well-being.
  • It is measured non-invasively using ultrasonography.
  • The standard technique is the four-quadrant method, where the deepest vertical pockets of fluid in four uterine quadrants are measured and summed.
  • Normal AFI values are generally between 5 cm and 24 cm.

Why Other Options Were Wrong

  • Option A: The Leopold maneuver is a series of four physical palpation techniques used to determine the fetus's lie, presentation, and position within the uterus.
  • Option B: Ballottement is a physical examination technique where the examiner taps the uterus to feel the rebound of the fetus. It is a probable sign of pregnancy and gives a rough sense of the fluid environment but does not provide a quantitative measurement.
  • Option C: Measuring abdominal girth (or fundal height) tracks the overall growth of the uterus. It is an indirect and non-specific measure that can be influenced by maternal weight, fetal size, and multiple gestations, not just amniotic fluid volume.

Related Visual

Visual explanation — Related Visual
Clinical Relevance
  • Nursing practice connection: This is primarily an exam-oriented knowledge point with limited direct bedside application, so retain Measurement of Amniotic Fluid Index (AFI) as background academic context rather than a clinical decision trigger.
  • AFI measurement is a critical component of fetal surveillance, especially in high-risk pregnancies, to detect oligohydramnios (low fluid) or polyhydramnios (high fluid).
  • Abnormal AFI can indicate potential problems such as fetal renal anomalies, gastrointestinal obstruction, placental insufficiency, or fetal distress, prompting further investigation and management.
  • What if? If a full AFI cannot be measured (e.g., due to fetal position or maternal obesity), the single deepest pocket (SDP) measurement can be used as an alternative. An SDP of less than 2 cm suggests oligohydramnios, and greater than 8 cm suggests polyhydramnios.
How to Approach the Question
  • Identify the core of the question: It asks for the specific method to 'measure' the 'Amniotic Fluid Index'.
  • Recognize that the term 'index' implies a quantitative, standardized measurement, not a qualitative assessment.
  • Analyze the options: Leopold maneuver, ballottement, and abdominal girth are all manual, physical examination techniques that provide qualitative or non-specific information.
  • Consider the capabilities of each option. Ultrasonography is a diagnostic imaging technology capable of providing precise, objective measurements of internal structures and fluids.
  • Conclude that ultrasonography is the only option suitable for calculating a quantitative value like the Amniotic Fluid Index.
Concept Tested & Keywords
  • Concept Tested: Measurement of Amniotic Fluid Index (AFI)
  • Stem keywords: Amniotic fluid index, measured by
  • Lead-in keywords: BEST, MOST RELEVANT CLUE

Question ID

QpGsq-kHgfR0VN2Zex4LlO

Reference Book

E6 Obstetrics Williams p. 49-70

E6 Comprehensive Textbook of Community Health Nursing for BSc Nursing Students Part 2 — Subpart A (pp 1-275 of 550) p. 199-201

Practise the full JSSH Staff Nurse - 2019

Attempt every question from this paper in a timed mock, then review the full solution for each one.

More Multiple Pregnancy, Amniotic Fluid Disorders, Abnormalities of Placenta and Cord Questions

More JSSH Staff Nurse - 2019 Questions